Ovation Technical Specifications

Direct Vent / Top Vent (Model WG3)

Natural Gas

L.P. Gas

Min/Max Input (BTU/hr)

25,000-37,000

28,000-35,000

Min/Max Output (BTU/hr)

19,000-28,120

22,120-27,650

Steady State Efficiency

76%

79%

Direct Vent / Rear Vent (Mode WG4)

Min/Max Input (BTU/hr)

24,000-36,000

25,000-33,000

Min/Max Output (BTU/hr)

18,480-27,720

19,500-25,740

Steady State Efficiency

77%

78%

B-Vent (Model WG5)

Min/Max Input (BTU/hr)

25,000-37,000

28,000-35,000

Min/Max Output (BTU/hr)

18,500-22,200

20,720-25,800

Steady State Effeciency

74%

74%

Minimum Clearance  to Combusitbles

Sidewall

12" - 305mm

Backwall

2" - 51mm

Adjacent Wall Corner

4" - 102mm

Fireplace Insert Model

Min/Max Input (BTU/hr)

24,000-36,000

25,000-33,000

Min/Max Output (BTU/hr)

17,520-26,280

18,500-24,420

Steady State Effeciency

73%

74%

Insert Shrouds

Small

28.5" x 40.75"

Large

32" x 44"

Picture
Picture

©1998 Pyro Industries Site Design: Arbeit Communications, Inc.